STATION 01 ● no server --:--:--
Probe identification
Test tier
Tier 1Standard
Tier 2Extended
Tier 3Life Test
Tier 47-hr Warranty
Every probe at manufacture. 35-min ramp, pass/fail at target temp.
Pass thresholds — TEG operating limits
Manufacturer rated max: 250°C hot / 50°C cold  ·  Optimal endurance: 240–245°C hot / 50–55°C cold
Test session
00:00
Ready
Pre-heat (15 min) Cook Cool-down (10 min)
Hot side (TC1)
°C
Awaiting reading
Cold side (TC2)
°C
Awaiting reading
Configure probe details and select a test tier to begin.
0
Total Tests
0
Passed
0
Failed
Pass Rate
0
Total Probe-Hrs
All probe records
Records are write-once and cannot be deleted
Probe IDDateTierCooking Cycle BatchTechHot@targetCold@target Session (min)Cumul. (hrs)ResultIntegrity
Load probe certificate
Lab settings
Enter the IP address shown when the server starts. All stations on the same WiFi network should use the same URL. Records are also always saved locally as backup.
Electric chamber — PID setpoint reference
Recommended: single fixed setpoint — 250°C. The chamber holds 250°C. The probe hot side stabilises at 240–245°C — within the TEG optimal endurance range. Any single-setpoint PID works (REX-C100 ~$8, Inkbird ITC-100 ~$12). Do not exceed 250°C chamber setpoint — TEG manufacturer rated max is 250°C hot side.
DishChamber setpointExpected hot sideLog intervalReadings
Tea / Chai250°C240–245°C5 min~8
Ugali250°C240–245°C5 min~11
Rice250°C240–245°C5 min~13
Githeri (soaked)250°C240–245°C5 min~23
Dry Maize250°C240–245°C5 min~29
Beans (soaked)250°C240–245°C5 min~23
Beans (unsoaked)250°C240–245°C5 min~41
Note: t=35 min is when 228°C / 52°C was first confirmed in field testing — not the session end. Temperatures continue rising beyond this point. The PASS window is: hot ≥ 228°C AND ≤ 250°C (TEG max), cold ≤ 50°C. Any reading above 250°C hot side is flagged as an OVER-LIMIT warning on the certificate.
Cooking duration reference — charcoal jiko
Audit log — all station activity
Append-only · cannot be cleared
TimestampStationActionDetail
Integrity verification — all stored records
Export all records to CSV
Downloads every probe test record from this station — all tiers, cooking cycles, integrity hashes.
Checking sync status…
0
Total tests
0
Today
0
Passed
0
Failed
0
Over-limit
All probe records — this station
Probe IDDateTierCooking cycle / session BatchTechHotCold SessionCumul. hrsResultIntegrity
This view shows records from this station only. To view all stations in one place, open the manager dashboard on the server: No server URL configured — enter one in Settings to enable cross-station view.